0.75 MMBTU 1500# Sour Line Heater

CAD $18,000 OBO

Listing Details

CategoryLine Heater
Listing ID21041
StatusAvailable
# of Units Available1
PriceCAD $18,000 OBO
Deal PreferenceFor Sale
Price TypeTotal
PackageD-11-B / 93-P-9
CertificationFuelled Certified
Year2008
Make/ManufacturerNWP Industries Inc
Serial Number1477
ServiceSour
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Line Heater Details
Burner Management SystemYes
Inlet Connection Diameter3 Inches
Inlet Connection Rating1500 ANSI
Outlet Connection Diameter3 Inches
Outlet Connection Rating1500 ANSI
Rated Capacity750000 BTU/hr
Notes

Flame Arrested Burner Tag*
Manufacturer: Zirco
Model: FAH18-12A
Serial#: 0803-893

Manufacturing Tag*
Manufacturer: NWP Industries Inc
Size: 42" x 12'
Firetube Size: 12"
Capacity: 750000 BTU/HR
Year Built: 2008

Coil A Tag*
W
RT-100
HT
Manufacturer: NWP Industries Inc
Size: 3" 1500#
MAWP: 3125 PSI at 200 F
MDMT: -20 F at 3125 PSI
Serial#: 1477
Year built: 2008
CRN: P9407.213
A#: 581121

Coil B Tag*
W
RT-100
HT
Manufacturer: NWP Industries Inc
Size: 3" 1500#
MAWP: 3125 PSI at 200 F
MDMT: -20 F at 3125 PSI
Serial#: 1477
Year built: 2008
CRN: P9407.213

Fuel Gas Scrubber Tag*
Manufacturer: NWP Industries Inc
Size: 8 5/8" x 2'
MAWP: 285 PSI at 100 F
MDMT: -20 F at 285 PSI
Serial#: 1419
Year Built: 2007
CRN: OH7347.231

Serials#: "1477"

A#: "581121"

CRN: "P-9407.231"

Certified Report

Location
Yard

D-11-B / 93-P-9

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

Unknown

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A51672

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Dawson Creek, British Columbia

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

D-11-B / 93-P-9
View package

Related Listings