0.75MMBTU 2.5" 1500# Sweet Line Heater

Contact for Pricing

Listing Details

CategoryLineHeater
Listing ID15112
StatusAvailable
# of Units Available1
Deal PreferenceFor Sale
Price TypeTotal
Package SE1/4 12-072-06 W6M
CertificationFuelled Certified
Year2002
Make/ManufacturerOpsco Industries
ServiceSweet
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Line Heater Details
Inlet Connection Diameter2.5"
Rated Capacity750,000 BTU/hr
Notes

Description: Line Heater Tag*
Serial: 03-3643-4-1/2
Year: 2002
Coil Size #1: 2" (NPS SCH: 160)
CRN: F3090.213
Coil Size #2: 3" (NPS SCH: 80)
Coil #1 MAWP: 23271 KPA (3375 PSI) at 93°C
Coil #2 MAWP: 9308 KPA (1350 PSI) at 93°C
Coil #1 Test Press: 38319 KPA
Coil #2 Test Press: 15307 KPA
RT 10%
Corr Allow: 0.0625"
A#: 476218
DIA: 42" OD
Length: 15'

Flame Arrested Burner Tag*
Model: SB20-10H
BTU: 750,000
Burner: 2.5"
ORF Size: 3/16"

Ansi In: 1500

Ansi Out: 600

Mawp In: 3375

Mawp Out: 1350

Certified Report

Location
Yard

Ovintiv - GP Storage Yard - SE1/4 12-072-06 W6M

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

No

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

No

Vessel Registrations
Provincial Vessel RegistrationsAB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Grande Prairie, Alberta

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

SE1/4 12-072-06 W6M
View package

Related Listings