1.5 MMBTU 3" 1500# Sour Line Heater

Contact for Pricing

Sold

Listing Details

CategoryLineHeater
Listing ID21045
StatusSold
CertificationFuelled Certified
Year2008
Make/ManufacturerNWP Industries Inc
Serial Number1470
ServiceSour
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Line Heater Details
Burner Management SystemYes
Inlet Connection Diameter3"
Inlet Connection Rating1,500 ANSI
Outlet Connection Diameter3"
Outlet Connection Rating1,500 ANSI
Rated Capacity1,500,000 BTU/hr
Notes

Flame Arrested Burner Tag*
Manufacturer: Zirco
Model: FAH24-18A
Serial#: 0803-671

Manufacturer Tag*
Manufacturer: NWP Industries Inc
Size: 48" x 16'
Fire Tube Size: 18"
Capacity: 1500000 BTU/HR
Year Built: 2008

Coil A Tag*
Manufacturer: NWP Industries Inc
W
RT-100
HT
Size: 3" 1500#
MAWP: 3125 PSI at 200 F
MDMT: -20 F at 3125 PSI
Serial#: 1470
Year Built: 2008
CRN: P-9407.213
A#: 581145

Coil B Tag*
Manufacturer: NWP Industries Inc
W
RT-100
HT
Size: 3" 1500#
MAWP: 3125 PSI at 200 F
MDMT: -20 F at 3125 PSI
Serial#: 1470
Year Built: 2008
CRN: P-9407.213

Coil C Tag*
Manufacturer: NWP Industries Inc
W
RT-100
HT
Size: 3" 1500#
MAWP: 3125 PSI at 200 F
MDMT: -20 F at 3125 PSI
Serial#: 1470
Year Built: 2008
CRN: P-9407.213

Coil D Tag*
Manufacturer: NWP Industries Inc
W
RT-100
HT
Size: 3" 1500#
MAWP: 3125 PSI at 200 F
MDMT: -20 F at 3125 PSI
Serial#: 1470
Year Built: 2008
CRN: P-9407.213

Serial#: "1470"

A#: "581145"

CRN: "P-9407.213"

Certified Report

Location
Yard

D-11-B / 93-P-9

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

Unknown

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A51677

Need Help?


Virtual Tour

Location

Dawson Creek, British Columbia

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support