1.0 MMBTU 5031 PSI Sour Line Heater

Contact for Pricing

Listing Details

CategoryLineHeater
Listing ID15127
StatusAvailable
# of Units Available1
Deal PreferenceFor Sale
Price TypeTotal
Package Edson Boneyard
CertificationFuelled Certified
Year2012
Make/ManufacturerMAR-QUINN
ServiceSour
ConditionUsed
Fuelled Condition Rating
C
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Line Heater Details
Burner Management SystemYes
Rated Capacity1,000,000 BTU/hr
Notes

Description: Line Heater Tag: Coil #1 & #2
CA (in): 0.125
MAWP: 5031 PSI at 200°F
MDMT: -20°F at 5031 PSI
MAT'L Spec: SA-333-GR6
MAT'L Size (in): NPS 3
MAT'L Thick (in): XXH
RT (%): 100
PWHT: 1HR. 1150 F
Code: B31.3

Flame Arrested Burner Tag:
Model: FAB24-12A
BTU: 1.0MM
Burner: 3 Primary Air
ORF Size: 7/32"
Serial No: 1209-711
ORIFICE Size (in): #13"
Arrestor Size (in): 24"
Energy Input (BTU): 812161
MAX Input (BTU): 979836
Main Burner Press (PSI): 9 PSI

Ansi In: 2500

Ansi Out: 2500

Mawp In: 5031

Mawp Out: 5031

Certified Report

Location
Yard

Edson Boneyard

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

Unknown

Service
Has equipment been preserved? If so, when?

No

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Edson, Alberta

This equipment is Fuelled Certified.