10" x 4' 655 PSI Separator Package

Contact for Pricing

Listing Details

CategorySeparator
Listing ID22776
StatusAvailable
# of Units Available2
Deal PreferenceFor Sale
Price TypeTotal
PackageFroth Treatment Test Facility - 13-13-25-5W5
CertificationFuelled Certified
Year2009
Make/ManufacturerTarpon Energy Services
Serial Number09-099-VS1
ServiceUnknown
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Vessel Details
Diameter10"
Length4'
OrientationVertical
Pressure Rating655 PSI
CRN / A#["U9352.2 / 595479"]
Notes

Quantity: (x2)

Separator Tag 1*
Make: Tarpon Energy Services
W RT-1
MAWP: 655 PSI at 300°F
MDMT: -20°F at 655 PSI
Serial: 09-099-VS2
Year: 2009
CRN: U9352.2
A#: 595480
Type: Vertical Separator
Shell MAT'L: SA-16-B
Shell THK: 0.5"
Tag: 100-V-102A
DIA: 10"
Length: 4'

Separator Tag 2*
Make: Tarpon Energy Services
W RT-1
MAWP: 655 PSI at 300°F
MDMT: -20°F at 655 PSI
Serial: 09-099-VS1
Year: 2009
CRN: U9352.2
A#: 595479
Type: Vertical Separator
Shell MAT'L: SA-16-B
Shell THK: 0.5"
Tag: 100-V-101A
DIA: 10"
Length: 4'

Certified Report

Location
Yard

Froth Treatment Test Facility - 13-13-25-5W5

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

No

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Unknown

Vessel Registrations
Provincial Vessel RegistrationsAB
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A53065

Need Help?


Location

Jumping Pound, Alberta

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

Froth Treatment Test Facility - 13-13-25-5W5
View package