4" 600 ANSI Meter Run

USD $863 OBO

Listing Details

CategoryMetering Equipment
Listing ID20838
StatusAvailable
CertificationFuelled Certified
Make/ManufacturerDANIEL
Serial Number11510373
ServiceUnknown
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Metering Equipment Details
Meter Diameter4 Inches
PackagedNo
Pressure Rating1480 PSI
Notes

16 various size meter runs

Meter Run Tag*
Line Bore: 3.0"
Model: 500DC10
Seal Plate Gap: 0.562"
ANSI: 600#
Serial: D03509C
Plate THK: 0.125"
CWP: 1480 PSI
CRN: 0F2015.213
CanAlta

Meter Run Tag*
Line Bore: 5.068"
Model: 53SC0
Plate Seal Gap: 0.562"
ANSI: 600#
Plate THK: 0.125"
Serial: 167747
CWP: 1480 PSI
MAT'L: A216WCB
CRN: 0F2015.213
CanAlta

Meter Run Tag*
Size: 3"
Line Bore: 2.9"
Serial: 10330454
Class: 600
CWP: 1480 PSI
Cat #: 075DCT
Plate THK: 0.125"
MAT'L: A216WCB
DANIEL

Meter Run Tag*
Size: 4"
Class: 600#
Line Bore: 3.826"
Serial: 11510373
CWP: 1480 PSI
Plate THK: 0.125"
DANIEL

CRN: 0F2015.213 / 0F2015.213
Serials: D03509C / 167747 / 10330454 / 11510373

Certified Report

Location
Yard

San Antonio - Eagle Ford - Gonzales Yard

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

No

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

No

Vessel Registrations
Provincial Vessel RegistrationsAB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A50993

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

San Antonio, Texas

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

San Antonio - Eagle Ford - Gonzales Yard
View package

Related Listings