16" x 24' (EST) 1300 PSI Sweet Dehydrator Package

Listing Details

CategoryDehydrator
Listing ID15577
StatusAvailable
# of Units Available1
Deal PreferenceFor Sale
Price TypeTotal
Package 06-31-009-14 W4
CertificationFuelled Certified
Year1987
Make/ManufacturerPresson Manufacturing LTD
ModelV-100
Serial Number426020
ServiceSweet
ConditionUsed
Fuelled Condition Rating
C
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Dehydrator Details
Glycol Flash TankYes
Glycol Pumps1
Glycol Pump DriveElectric Motor
MAWP1300 PSI
Vessel Details
Contactor Diameter16 Inches
Contactor Length24 Feet
Vessel OrientationVertical
Pressure Rating1300 PSI
Notes

Flame Arrested Burner Tag*
Serial: 426040
Job No: B426004
Year: 1987
180GB
Presson Manufacturing

Absorber Tower Tag*
DIA: 16"
W RT-1
A#: 226851
Serial: 426020
CRN: H0521.2
MAWP: 1300 PSI at 150°F
Tag No: V-100
Year: 1987
Corr Allow: 0.0625"
Shell THK / MAT'L: 0.843" / SA106B
Head THK / MAT'L: 0.740" / SA51670
Weight: 5000 LBS

Meter Tag*
Daniel Industries
Size: 3"
ANSI P.S.P.R: 600#
CAT No: 015
Line Bore: 3.068
CWP LBS: 1480 LBS
MAT'L ASTM No: A-216
Serial: 86050205
Plate THK: 0.125"
Trim: A

KIMRAY Pump Tag*
Model: 4015PV
Max W.P: 1500#
Gal/hr: 40
Max Strokes/min: 40
Serial: 2091100862

Fliter Tag*
MAWP: 125 CWP at 150°F
Serial: PMS1-3
CRN: 03745.2
Year: 1987

A#: 226851 (1)
CRN: H0521.2 (1) / 03745.2 (2)
Serials: 426040 (1) / 426020 (2) / 86050205 (3) / 2091100862 (4) / PMS1-3 (5)

Certified Report

Location
Yard

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

Yes

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

Yes

Have vessels been cleaned out

Unknown

Shiploose items

No

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A49982

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Medicine Hat, Alberta

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

06-31-009-14 W4
View package

Related Listings