24" x 10' 1425 PSI Sweetening Skid

Contact for Pricing

Sold

Listing Details

CategoryGasSweeteningEquipment
Listing ID20833
StatusSold
CertificationFuelled Certified
Year2011
Make/ManufacturerUltraFab Industries
Serial Number119-7203
ServiceSour
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Vessel Details
Vessel Diameter24"
Vessel Length10'
Vessel OrientationVertical
Pressure Rating1,425 PSI
Notes

2 identical units

Identifier Tag*
Sweetening System UltraFab 48" H2S

Vertical Contactor Tag*
W RT-1 HT
MAWP: 1425 PSI at 140°F
MDMT: -20°F at 1425 PSI
Serial: 130549
Year: 2011
Shell THK: 1.00"
Shell MAT'L: SA516-70N
Head THK: 1.00"
Head MAT'L: SA516-70N
CA: 0.125"
CRN: V5212.2
A#: 610037

Filter Tag*
MAWP: 285 PSIG at 650°F
MDMT: -20°F at 285 PSIG
CRN: OH5148.21345
Serial: 8285.1435
Service: Fuel Gas

Vertical Separator Tag*
W RT-1 HT
MAWP: 1425 PSI at 140°F
MDMT: -20°F at 1425 PSI
Serial: 130561
Year: 2011
Shell THK / MAT'L: 0.844" / SA106B
Head THK / MAT'L: 0.875" / SA516-70N
CA: 0.0625"
CRN: V5211.2
A#: 610047

Ultra Industries Tag*
Serial: 119-7203
Year: 2011

Primary Chemical Pump Tag*
Serial: 50-1234-1-1/4
P/N: BR5008LPT7411
Max Disc: 2000 PSI
Max Supply: 50 PSI

Secondary Chemical Pump Tag*
Serial: 50-1235-1-1/4
P/N: BR5008LPT7411
Max Disc: 2000 PSI
Max Supply: 50 PSI

A#: 610037 / 610047
CRN: V5212.2 / V5211.2
Serials: 130549 / 8285.1435 / 130561 / 119-7203 / 50-1234-1-1/4 / 50-1235-1-1/4

Certified Report

Location
Yard

San Antonio - Eagle Ford - Gonzales Yard

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

No

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

No

Vessel Registrations
Provincial Vessel RegistrationsAB
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A50974

Need Help?


Virtual Tour

Location

San Antonio, Texas

Documents

24" x 10' 1425 PSI Sweetening Skid 40
24" x 10' 1425 PSI Sweetening Skid 41
24" x 10' 1425 PSI Sweetening Skid 45

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

San Antonio - Gonzales Yard
View package

Related Listings