2 HP Pump Package

Contact for Pricing

Listing Details

CategoryPump
Listing ID22773
StatusAvailable
# of Units Available1
Deal PreferenceFor Sale
Price TypeTotal
PackageFroth Treatment Test Facility - 13-13-25-5W5
CertificationFuelled Certified
Year2009
Make/ManufacturerFMC Technologies
ModelM0608
Serial Number 041509A10129
ServiceUnknown
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Pump Details
MAWP390 PSI
PackagedNo
Pump Typeunknown
Driver Details
Driver MakeReliance Electric
Driver ModelB471824
Driver Serial NumberB471824-010
Driver TypeUnknown
Driver Fuel TypeUnknown
Driver Horse Power2 HP
Driver Rating2 HP
Driver Speed1,160 RPM
Notes

Pump Tag*
Make: FMC Technologies
Model: M0608
Part No: P541536
Serial: 041509A10129
Power: 0.5 KW
HP: 0.6
Disch. Press: 27 BARG (390 PSI)
Suc. Press: 4 BARG (60 PSI)
Flow Rate: 0.6 M^3/H
RPM: 484
Year: 2009

Electric Driver Tag*
Make: Reliance Electric
Serial: B471824-010
Model: B471824
Frame: L184T
HP: 2
Volts: 460
Phase: 3
RPM: 1160
AMps: 2.80
HZ: 15-60
Weight: 141 LBS
KW: 1.5

Certified Report

Location
Yard

Froth Treatment Test Facility - 13-13-25-5W5

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

No

Shiploose items

No

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Unknown

Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A53063

Need Help?


Location

Jumping Pound, Alberta

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

Froth Treatment Test Facility - 13-13-25-5W5
View package

Related Listings