Listing Details
Category | RefrigerationPlant |
---|---|
Listing ID | 22876 |
Status | Available |
# of Units Available | 1 |
Price | USD $575,000 OBO |
Deal Preference | For Sale |
Price Type | Total |
Package | La Pryor, TX Refrigeration |
Certification | Fuelled Certified |
Year | 2014 |
Make/Manufacturer | Wedge Energy Services |
Serial Number | 0614HRC3-2 |
CO2E Savings | 220.12 Tonnes |
Service | Sweet |
Condition | Used |
Fuelled Condition Rating | Condition A New/Unused Equipment Condition B Ready to go into operation with minor service (tune-up). Used but has been overhauled. Condition C Requires Overhaul but components are present and not damaged/used beyond repair. Condition D Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair. Condition E Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver). |
Refrigeration Plant Details | |
Plant Type | Mechanical Refrigeration |
Compressor Details | |
Compressor Make | Genuine Carlyle |
Compressor Model | 5H86-A219 |
Compressor Serial Number | 3815UA1285 |
Compressor Type | Screw |
Vessel Details | |
Vessel Orientation | Vertical |
Design Pressure Rating | 1,440 PSI |
Driver Details | |
Driver Make | Siemens |
Driver Model | XP100 |
Driver Serial Number | Q2-L13T1496XPE |
Driver Type | Electric Motor |
Driver Fuel Type | Other |
Refrigeration Horse Power | 125 HP |
Driver Rating | 125 HP |
Driver Speed | 1,785 RPM |
Notes | |
Mechanical Refrigeration Units
Condensate Stabilization Units
GenSet
2 MMSCFD Storage Bullet Tag*
Storage BUllet 2 Tag*
Compressor Driver Tag*
Compressor Tag*
Compression Discharge Separator Tag*
Refrigerant Surge Tank Tag*
Inlet Gas Separator Tag*
Heat Exchanger Tag*
Vessel Tag*
Small Cooler Tag*
Dehydration Unit Tag*
Flame Arrested Burner Tag*
Stabilizer Column Tag*
Generator Tag*
Generator Driver Tag*
Meter Run*
| |
Certified Report
Location | |
Yard | La Pryor, TX Refrigeration |
---|---|
Status | |
Equipment Still in Operation | No |
Does the skid have skirting that needs to be removed | No |
Equipment still connected to piping | No |
Equipment still welded down to piles | No |
Equipment on a gravel pad | No |
Electrical still connected to the equipment | No |
Have vessels been cleaned out | Unknown |
Shiploose items | Yes |
Service | |
Has equipment been preserved? If so, when? | Unknown |
Site Logistics | |
Equipment accessibility in yard or work site | |
Access into work site | |
Any road use agreement to access site | Unknown |
Equipment Appearance | |
Missing Parts | |
Corrosion | |
Animal Infestation | |
Overall cleanliness of package | |
Notes | |
A54497 |