20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1)

Listing Details

CategoryRefrigeration Plant
Listing ID13788
StatusAvailable
# of Units Available1
Deal PreferenceFor Sale
Price TypeTotal
PackagePeyto 09-34-053-20 W5M
CertificationFuelled Certified
Year2011
Make/ManufacturerALCO Gas & Oil
ServiceSweet
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Refrigeration Plant Details
Compressor Details
Compressor TypeUnknown
Vessel Details
Vessel OrientationUnknown
Driver Details
Driver TypeUnknown
Driver Fuel TypeUnknown
Notes

Description: Plant is equipped with propane refrigeration which yields temperatures of -20 to -25 degrees Celsius on the cold separator.

DE-Ethanizer Tower
Serial: 2011-8193-15
CRN: U-3630.2
A#: 583731
MAWP: 400 PSI at 150F
MDMT: -20F at 400 PSI
Tag#: T-600
CA: 0.0625"

Gas Chiller Tag*
Serial: 2011-8193-02
CRN: U-3574.2
A#: 583711
MAWP: 300 PSI at 150F
MDMT: -20F at 300 PSI
CA: 0.0625"
Tag #: E-430

Heating Coil Tag*
Serial: 2011-8193-03
CRN: V-5020.2
Year: 2011
MAWP: 700 PSI at 150F
MDMT: -20F at 700 PSI
CA: 0.0625"

Reboiler Tag*
Serial: 2011-8193-05
Year: 2011
Duty: 600000 BTU
Tag#: H-470

Glycol Flash Tank Tag*
Serial: 2011-8193-06
Year: 2011
CRN: U-3622.2
A#: 583725
MAWP: 150 PSI at 200F
MDMT: -20F at 150 PSI
Tag#: V-190
CA: 0.0625"

Certified Report

Location
Yard

Peyto - 09-34-053-20 W5M

Status
Equipment Still in Operation

Yes

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

Yes

Equipment still welded down to piles

Yes

Equipment on a gravel pad

Yes

Electrical still connected to the equipment

Yes

Have vessels been cleaned out

Unknown

Shiploose items

Unknown

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Edson, Alberta

Documents

20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1
20 MMSCFD 600 ANSI Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 1) 1

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support