20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3)

Listing Details

CategoryRefrigeration Plant
Listing ID13906
StatusAvailable
# of Units Available1
Deal PreferenceFor Sale
Price TypeTotal
Package 09-34-053-20 W5M
CertificationFuelled Certified
Year2007
Make/ManufacturerALCO Gas & Oil
ServiceSweet
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Refrigeration Plant Details
Compressor Details
Compressor TypeUnknown
Vessel Details
Vessel OrientationUnknown
Driver Details
Driver TypeUnknown
Driver Fuel TypeUnknown
Notes

Description: Gas Chiller Tag*
Serial: 2007-7796-02
CRN: U-3754.2
Year: 2007
MAWP: 700 PSI at 150°F
MAEWP: 0 PSI at 150°F
MDMT: -20°F at 700 PSI
Tag: TUBESIDE
CA: 0.0625
Hydro: 910 PSI

Flame Arrested Burner Tag*
Serial: 0710-696
Model: FAB18-12A
Burner: 2-1/2
Orf Size: MTD16
BTU: 600000
Arrestor Size: 20"
Energy Input: 356425 BTU
Max Input: 965,982 BTU
Main Burner Press: 11 PSI

Compressor Tag*
Serial: 882773
Model: P8WB
LEAK (PSIG): HP 313 / LP185
HYD (PSIG): HP 470 / LP 470

Packed DE-Ethanizer Tower Tag*
Serial: 2007-7796-05
CRN: U-3630.2
A#: 584433
Year: 2007
MAWP: 400 PSI at 150°F
MAEWP: 0 PSI at -20°F at 400 PSI
CA: 0.0625
HYDRO: 520 PSI
Head: SA516-70MT / 0.28"
Shell: SA106B / 0.375"

Propane Suction Scrubber Tag*
Serial: 2007-7796-08
CRN: U-3652.2
A#: 584457
Year: 2007
MAWP: 300 PSI at 200°F
MAEWP: 0 PSI at 200°F
MDMT: -20°F at 300 PSI
CA: 0.0625"
Hydro: 390 PSI

Heating Coil Tag*
Serial: 2007-7796-08
CRN: U-3652.2
Year: 2007
MAWP: 1350 PSI at 200°F
MAEWP: 300 PSI at 200°F
MDMT: -20°F at 1350 PSI
CA: 0.0625"
Hydro: 1755 PSI

3PH Glycol Flash Tank Tag*
Serial: 2007-7786-07
CRN: U-3622.2
A#: 584437
MAWP: 150 PSI at 200°F
MAEWP: 0 PSI at 200°F
MDMT: -20°F at 150 PSI
CA: 0.0625"
Hydro: 195 PSI

Low Temp Separator Tag*
Serial: 2007-7796-03
CRN: U-3756.2
A#: 584438
Year: 2007
MAWP: 700 PSI at 150°F
MDMT: -20°F at 700 PSI
CA: 0.0625"
Hydro: 910 PSI

Certified Report

Location
Yard

Peyto - 09-34-053-20 W5M

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

Yes

Equipment still welded down to piles

Yes

Equipment on a gravel pad

No

Electrical still connected to the equipment

Yes

Have vessels been cleaned out

Unknown

Shiploose items

No

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Edson, Alberta

Documents

20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1
20 MMSCFD Mechanical Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3) 1

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support