Listing Details
Category | Dehydrator |
---|---|
Listing ID | 15544 |
Status | Available |
# of Units Available | 1 |
Deal Preference | For Sale |
Price Type | Total |
Package | 02-31-013-20 W4 |
Certification | Fuelled Certified |
Year | 1,990 |
Make/Manufacturer | Presson Manufacturing LTD |
Serial Number | 4846-21 |
Service | Sour |
Condition | Used |
Fuelled Condition Rating | Condition A New/Unused Equipment Condition B Ready to go into operation with minor service (tune-up). Used but has been overhauled. Condition C Requires Overhaul but components are present and not damaged/used beyond repair. Condition D Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair. Condition E Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver). |
Dehydrator Details | |
Glycol Flash Tank | Yes |
Glycol Pumps | 2 |
Glycol Pump Drive | Electric Motor |
MAWP | 1,440PSI |
Reboiler Duty | 180,000BTU/hr |
Vessel Details | |
Vessel Capacity | 180,000BBL |
Contactor Diameter | 20Inches |
Contactor Length | 20Feet |
Vessel Orientation | Vertical |
Pressure Rating | 1,440PSI |
Notes | |
Reboiler Tag*
Separator Tag*
Contactor Tag*
Electric Motor Tag*
Flash Tank Tag*
Pump Tag*
Fuel Gas Separator Tag*
Pump Tag*
A#: 2666589 (1) / 2666905 (2) CRN: K1981.2 (1) / K1982.2 (2) / 16865.2 (3) / F6864.2 (4) / D-775.213 (5) Serials: 4846-60 (1) / 4846-20 (2) / 4846-21 (3) W0500 (4) / 4846-22 (5) / CA1980A501 (6) / 4846-23 (7) / LM-1978 (8) | |
Certified Report
Location | |
Yard | SanLing - 02-31-013-20 W4 |
---|---|
Status | |
Equipment Still in Operation | No |
Does the skid have skirting that needs to be removed | No |
Equipment still connected to piping | No |
Equipment still welded down to piles | No |
Equipment on a gravel pad | No |
Electrical still connected to the equipment | Yes |
Have vessels been cleaned out | Unknown |
Shiploose items | Yes |
Service | |
Has equipment been preserved? If so, when? | Unknown |
Site Logistics | |
Equipment accessibility in yard or work site | |
Access into work site | |
Any road use agreement to access site | No |
Vessel Registrations | |
Provincial Vessel Registrations | AB |
Equipment Appearance | |
Missing Parts | |
Corrosion | |
Animal Infestation | |
Overall cleanliness of package | |
Notes | |
A49949 |
Virtual Tour
Location
Medicine Hat, Alberta
This equipment is Fuelled Certified.
- Visually inspected and catalogued by Fuelled trained representatives