Listing Details
Category | Pump |
---|---|
Listing ID | 22227 |
Status | Available |
Certification | Fuelled Certified |
Year | 2008 |
Make/Manufacturer | Waterflood Service and Sales |
Model | Gardner Denver TQB (GD-25T) |
CO2E Savings | 19.88 Tonnes |
Service | Sweet |
Condition | Used |
Fuelled Condition Rating | Condition A New/Unused Equipment Condition B Ready to go into operation with minor service (tune-up). Used but has been overhauled. Condition C Requires Overhaul but components are present and not damaged/used beyond repair. Condition D Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair. Condition E Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver). |
Pump Details | |
Packaged | Yes |
Pump Type | plunger |
Driver Details | |
Driver Make | Teco Westinghouse |
Driver Model | 324T 3PH 230 460V TEFC |
Driver Type | Electric Motor |
Driver Horse Power | 25 HP |
Driver Rating | 25 HP |
Driver details | 25HP Teco Westinghouse Frame 324T 3PH 230 460V TEFC. |
Notes | |
The boost pump is a Grundfos CRN 5-3 A-FGJ-G-V-HQQV The building is very clean and everything looks to be in good condition we drained the oil in the injection pump it was clean, the power end is very clean see attached pictures. Suction flange is 3” 150 and discharge flange is 2” 600 the suction comes in the north wall and discharge goes out the south wall see pictures attached. The filter pot is in good condition, plungers are 1-3/4” ceramic and the valves are AR valves we weren’t able to remove the valves there was ice built up on them. We replaced the valves back in September 2020 not long before it was taken out of service.
Pump Specs SPECIFICATIONS:
| |
Certified Report
Location | |
Work Site | Medicine Hat area 16-21 |
---|---|
Status | |
Equipment Still in Operation | No |
When was equipment last run | Mar 19, 2020 |
Does the skid have skirting that needs to be removed | No |
Equipment still connected to piping | Yes |
Equipment still welded down to piles | No |
Equipment on a gravel pad | Yes |
Electrical still connected to the equipment | Yes |
Have vessels been cleaned out | N/A |
Shiploose items | No |
Service | |
Has equipment been preserved? If so, when? | Unknown |
Site Logistics | |
Equipment accessibility in yard or work site | |
Access into work site | |
Any road use agreement to access site | Unknown |
Equipment Appearance | |
Missing Parts | |
Corrosion | |
Animal Infestation | |
Overall cleanliness of package | |
Notes | |
Inspection completed March 2023 The building is very clean and everything looks to be in good condition we drained the oil in the injection pump it was clean, the power end is very clean see attached pictures. Suction flange is 3” 150 and discharge flange is 2” 600 the suction comes in the north wall and discharge goes out the south wall see pictures attached. The filter pot is in good condition, plungers are 1-3/4” ceramic and the valves are AR valves we weren’t able to remove the valves there was ice built up on them. We replaced the valves back in September 2020 not long before it was taken out of service. Injection pump motor is a 25HP Teco Westinghouse Frame 324T 3PH 230 460V TEFC. |
Location
Agatha, Alberta
This equipment is Fuelled Certified.
- Visually inspected and catalogued by Fuelled trained representatives
- Immersive and credible data