Listing Details
Category | Separator |
---|---|
Listing ID | 13734 |
Status | Unavailable |
Certification | Fuelled Certified |
Year | 2012 |
Make/Manufacturer | Tarpon Energy Services |
Service | Sour |
Condition | Used |
Fuelled Condition Rating | Condition A New/Unused Equipment Condition B Ready to go into operation with minor service (tune-up). Used but has been overhauled. Condition C Requires Overhaul but components are present and not damaged/used beyond repair. Condition D Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair. Condition E Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver). |
Vessel Details | |
Diameter | 36 Inches |
Orientation | Vertical |
Pressure Rating | 609 PSI |
Vessel details | Dimensions: 36 |
Notes | |
Description: Tarpon Energy Services Process Building: Electrical: Volts: 120/208 Amps: 20 Phase: 3 Hertz: 60 Job #: 12-061 A#'s: 622285/622288/622291 Serial Number: 12-061VS1 / VS2 / VS3 Service: Sour Kootenay Test Separator V-4040: Serial Number: 12-061VS2 Year Built: 2012 CRN: V8562.231 A#: 622288 Vessel Type: Vertical Gas Separator MAWP: 609 PSI @ 473 F Group Separator V-4030: Serial Number: 12-061VS1 CRN: V8556.231 A#: 622285 Year Built: 2012 Vessel Type: Vertical Gas Separator MAWP: 609 PSI @ 473 F Produced Gas Separator V-5020: Serial Number: 12-061VS3 CRN: V8560.231 A#: 622291 Year Built: 2012 Vessel Type: Vertical Gas Separator MAWP: 229 PSI @ 302 F | |
Certified Report
Location | |
Yard | Cadotte Facility - 13-09-085-17 W5 |
---|---|
Status | |
Equipment Still in Operation | No |
Does the skid have skirting that needs to be removed | No |
Equipment still connected to piping | Yes |
Equipment still welded down to piles | Yes |
Equipment on a gravel pad | No |
Electrical still connected to the equipment | Yes |
Have vessels been cleaned out | No |
Shiploose items | Unknown |
Service | |
Has equipment been preserved? If so, when? | Unknown |
Site Logistics | |
Equipment accessibility in yard or work site | |
Access into work site | |
Any road use agreement to access site | Yes |
Vessel Registrations | |
Provincial Vessel Registrations | AB, BC, SK |
Equipment Appearance | |
Missing Parts | |
Corrosion | |
Animal Infestation | |
Overall cleanliness of package |
Virtual Tour
Location
Peace River, Alberta
This equipment is Fuelled Certified.
Benefits to purchasing Fuelled Certified equipment:
- Visually inspected and catalogued by Fuelled trained representatives
- Immersive and credible data