66" x 40' 3.5 MMBTU/HR Direct Fired Amine Reboiler

Sold

Listing Details

CategoryHeat Medium Package
Listing ID11376
StatusSold
CertificationFuelled Certified
Year2005
Make/ManufacturerPresser
Serial NumberB7227-60
ServiceSweet
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Notes

Description: Originally part of a 30 MMSCFD Amine Plant
The direct fired reboiler has been removed from the site and is yard stored.

AMINE REBOILER (SUBJOB -60)
- 3.5 MMBTU/hr (8,000 BTU's/hr/ft flux rate)
- 66" O.D. x 40'0" S/S X 50 psig @ 300ºF/-20ºF MDMT
- 0.125" C.A
- SHELL: 66" O.D. x 3/8" thick SA-516-70N plate
- HEADS: 66" O.D. x 3/8" thick 2:1 S.E. SA-516-70N plate
- FIRETUBE: 24" O.D. x 0.500" wall x 34'-0" SA-516-70N
- 100% radiography (per RT-1), PWHT
- STACK: 0.188" wall x 20'-0" ERW self supporting
- five (5) piece mitre
- burner assembly and fuel gas train supplied / installed by others
- INSULATION: 1 1/2" AF-530 fibreglass insulation c/w flat aluminum
jacket
- FUEL GAS PREHEAT COIL:
- 1" sch 80 SA-106B
- Design Int. Pressure: 285 psig @ 300ºF/-20ºF (0.0625" c.a)
- Design Ext. Pressure: 75 psig @ 300ºF/-20ºF ( 0.125" c.a)
- lift lugs
- integral 3'-6" surge capacity d/s of wier
- instrument enclosure (B-800)
- CRN #: T3485.2

Connections:
2 - 4" 150# RFWN nozzles (vapour outlets)
2 - 4" 150# RFWN nozzles (amine inlets)
1 - 4" 150# RFWN nozzle (amine outlet)
2 - 2" 150# RFWN nozzles (truck outs)
1 - 2" 150# RFWN nozzles (truck in)
4 - 2" 150# RFWN nozzles (TI, TT, TSHH, purge gas)
9 - 2" 150# RFWN nozzles (LG, LSL, LSLL, PI)
2 – 1" 6000# NPT coupling (fuel gas preheat)
1 - fabricated firetube manway, SA-516-70N
1 - 20" 150# RF manway c/w blind flange, bolting and davit
1 - 3" 150# RFWN nozzle (PSV)

Flame Arrested Burner Tag*
Model: FAH36/18-24A
Serial: 0510-830
ZIRCO

PREHEAT COIL TAG*
W RT-4 HT
A#: 525221
Serial: B7227-60
MAWP: 285PSI at 300°F
MDMT: -20°F at 285PSI
Year: 2005
CRN: T34852
CORR Allowance: 0.125"
Shell THK: 0.50"
Shell Material: SA106B

Reboiler Tag*
W RT-4 HT
A#: 525221
Serial: B7227-60
MAWP: 50PSI at 300°F
MDMT: -20°F at 50PSI
Year: 2005
CRN: T-34852
CORR Allowance: 0.125"
Shell THK: 0.50"
Shell Material: SA516-70N
TAG NO.: H-800
Head THK: 0.3125/ 0.4375
Had Material: SA516-70N

A#: 525221 (1)
CRN: T34852 (1) / T-34852 (2)
Serial: 0510-830 (1) / B7227-60 (2)

Certified Report

Location
Yard

Athabasca, Alberta

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Yes

Shiploose items

Yes

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

No

Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A51133

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Athabasca, Alberta

Documents

66" x 40' 3.5 MMBTU/HR Direct Fired Amine Reboiler 1

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Related Listings