Listing Details
Category | Dehydrator |
---|---|
Listing ID | 13083 |
Status | Available |
# of Units Available | 1 |
Deal Preference | For Sale |
Price Type | Total |
Package | D-80-F/94-H-12 |
Certification | Fuelled Certified |
Year | 1993 |
Make/Manufacturer | Alco |
Service | Sour |
Condition | Used |
Fuelled Condition Rating | Condition A New/Unused Equipment Condition B Ready to go into operation with minor service (tune-up). Used but has been overhauled. Condition C Requires Overhaul but components are present and not damaged/used beyond repair. Condition D Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair. Condition E Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver). |
Dehydrator Details | |
Glycol Pump Drive | Pneumatic |
MAWP | 1,440 PSI |
Reboiler Duty | 375 BTU/hr |
Vessel Details | |
Contactor Diameter | 36" |
Contactor Length | 28' |
Vessel Orientation | Horizontal |
Pressure Rating | 1,440 PSI |
Vessel details | Dimensions: 36 |
Notes | |
Description: Glycol Contactor Tag* RT-1 HT MAWP: 1440 PSI @ 130°F MDMT: -20°F @ 1440 PSI Serial: 930-4824-027 Year Built: 1993 CRN: K8962.2 A: 2835916 Reboiler Tag* MAWP: ATM Year Built: 2010 Serial: 2010-8057-01 375000 BTU Reboiler Gas Sweetener Tag* RT-1 HT 12.750 x 5'3" MAWP: 150 PSI @ 150°F MDMT: -20°F @ 150 PSI Serial: 93C-4824-09 Year Built: 1993 CRN: K8960.2 A: 2835923 | |
Certified Report
Location | |
Work Site | D-80-F/94-H-12 |
---|---|
Status | |
Equipment Still in Operation | No |
Does the skid have skirting that needs to be removed | N/A |
Equipment still connected to piping | N/A |
Equipment still welded down to piles | Yes |
Equipment on a gravel pad | N/A |
Electrical still connected to the equipment | N/A |
Have vessels been cleaned out | Unknown |
Shiploose items | N/A |
Service | |
Has equipment been preserved? If so, when? | Unknown |
Site Logistics | |
Equipment accessibility in yard or work site | |
Access into work site | |
Any road use agreement to access site | Yes |
Vessel Registrations | |
Provincial Vessel Registrations | AB |
Equipment Appearance | |
Missing Parts | |
Corrosion | |
Animal Infestation | |
Overall cleanliness of package |
Virtual Tour
Location
Fort St John, British Columbia
This equipment is Fuelled Certified.
Benefits to purchasing Fuelled Certified equipment:
- Visually inspected and catalogued by Fuelled trained representatives
- Immersive and credible data
- Fuelled logistical support