3.0 MMBTU Sour 900# Line Heater 6 Inlets

Contact for Pricing

Sold

Listing Details

CategoryLineHeater
Listing ID10925
StatusSold
CertificationFuelled Certified
Year2018
Make/ManufacturerRushton Gas and Oil Equipment Ltd.
ServiceSour
ConditionNew
Fuelled Condition Rating
A
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Line Heater Details
Inlet Connection Diameter4"
Outlet Connection Diameter4"
Rated Capacity3,000,000 BTU/hr
RuntimeHours
Notes

Description: 3.0 MMBTU/HR LINE HEATER

H-100 3.0 MMBTU/Hr. (Net Duty) Indirect Natural Gas Line Heater 84? OD x 20?-0? long flanged ends

1 Removable Firetube - 30? OD x 18'-0" Single Leg Length

1 36? OD x 5'-6" long horizontal expansion tank

1 Expansion Tank Access Ladder

FA/BRN-100 1 Flame Arrestor Rated for up to 3,000,000 MM BTU/hr (Net Duty), To fit a 30" firetube; c/w: Burner

VESSEL MATERIALS:

Shell: SA-252

End Plates: SA-44W

Flanges / O'lets: SA-105N

Saddles & Internals: SA-44W

REMOVABLE COILS:

6 individual coils constructed of (4) Passes of 4" Sch 80 SA-106-Gr.B Pipe c/w 4" CL 600 RF Ends, SA-105-N

MAWP 1,335 psig @ -20/250?F

1/8" Corrosion Allowance

Coil buttwelds to receive 100% RT

Coil to be registered in Alberta c/w CRN #

DESIGN CONDITIONS:

As per provided process run information

LINE HEATER ACCESSORIES:

TH 100 1 Jayco Thief Hatch model JT-8.1, 16oz pressure setting. 0.4 oz. vacuum relief

LG/GV 100 1 Redline Glass c/w Penberthy N7A Gauge Valve Sets, 1/2" MNPT malleable iron body, MAWP 490 Psig (Expansion tank)

TG/TW 101 1 Bimetal Thermometer, 1/2" NPT, center back mount, 50 to 500 ?F, dual scale, 3" dial, 9" stem, 304 SS case/ring/stem c/w Gaugetech Stepped Thermowell, 1/2" x 3/4" x 9" lg, 316 Stainless Steel construction, 7 1/2" "U" Length, 0.260" dia. Bore, MAWP 7000 Psig

LLSD 100 1 Electric Level Switch 2" MNPT, 316 Stainless Steel body/float, MAWP 1500 psig @ 400?F, NACE, -40?F

BAFF 64 1 Ball Valve 2" NPT, p/n MERM12B2, reg port, MAWP 2000 psig (LH Drain)

FUEL GAS INLET:

Assumed Fuel Gas Skid Edge Connection: 1" NPT, c/w 1" Pipe, SA-106B (100 psig inlet @ 60?F)

BAFF 44 1 Ball Valve 1" NPT,Reg Port, MAWP 2000 psig (Fuel gas inlet isolation)

BURNER CONTROLS:

BMS/TE/TSHH 120 1 Profire 2100 BMS Controller c/w dual process head connection 3/8" bore x 11.5", thermowell 3/4" NPT x 11.5" Stainless Steel, Dual Type K thermocouple

BAFF 43 1 NEO Cat. Ball Valve 1" NPT, p/n No. 2500, CSA 3.16 Certified, MAWP 2000 psig @ 100?F

STYF 40 1 Y-Strainer 1" NPT, YS-3000, MAWP 3000 psig

PRV 100 1 Pressure Regulator 1" NPT, 1/4" Port, w/ internal relief, ductile iron steel body, 5-20 Psig spring range, MAWP 500 Psig

PSLL 100 1 Electric Pressure Switch, 3-50 Psig pressure range, Set @ TBD Psig falling, MAWP 500 Psig

PG 120 1 Bottom Mount Pressure Indicator, 1/4" MNPT, 0-30 psig range, 2 1/2" face, MAWP 490 psig

NEIF 04 1 Needle Valve 1/4" FNPT x 1/4" FNPT, MAWP 6000 Psig (PG Isolation)

BAFF 20 1 Ball Valve 1/2" NPT, Reg port, MAWP 2000 psig (PSLL / PI Process Block, CSO)

SSV 100/110 2 Gas Shutoff Valve 1" NPT, MAWP 500 Psig

PSHH 100 1 Electric Pressure Switch, 3-50 Psig pressure range, Set @ TBD Psig rising, MAWP 500 Psig

PG 130 1 Bottom Mount Pressure Indicator, 1/4" MNPT, 0-30 psig range, 2 1/2" face, MAWP 490 psig

NEIF 04 1 Needle Valve 1/4" FNPT x 1/4" FNPT, MAWP 6000 Psig (PG Isolation)

BAFF 20 1 Ball Valve 1/2" NPT, Reg port, MAWP 2000 psig (PSHH / PI Process Block, CSO)

TCV 100 1 Control Valve, 1" NPT, 1/2" Trim (FloPro), Fail Closed, 0 to 35 psig Operating Range, 3 Springs have been removed from Actuator for soft actuation

EY 100 1 3-Way Solenoid Valve 1/4" NPT,0.09375" orifice, 0.12 Cv, 11.6 watts, MAWP 115 Psig

SCV 100 1 Speed Controller 1/4" NPT, Proof pressure 217.5 Psig, Free flow rate 340 Ft?/Hr, Controlled flow rate 250 Ft?/Hr, MAWP 145 psig

PG 140 1 Bottom Mount Pressure Indicator, 1/4" MNPT, 0-30 psig range, 2 1/2" face, MAWP 490 psig

NEIF 04 1 Needle Valve 1/4" FNPT x 1/4" FNPT, MAWP 6000 Psig (PG Isolation)

BAFF 43 1 NEO Cat. Ball Valve 1" NPT, p/n No. 2500, CSA 3.16 Certified, MAWP 2000 psig @ 100?F

Pilot Line:

BAFF 03 1 NEO Cat. Ball Valve 1/4" NPT, CSA 3.16 Certified, MAWP 2000 psig (Pilot Block)

PRV 110 1 67 CFR Pressure Regulator, 1/4" NPT, 0-35 psig range, MAWP 250 psig (vented)

PG 150 1 Bottom Mount Pressure Indicator, 1/4" MNPT, 0-15 psig range, 2 1/2" face, MAWP 490 psig

SSV 120 1 "Gas Shutoff Valve 1/4"" NPT, MODP 50 psig @ -40?C, C.S.A. 6.5 C/I listed
"

PG 160 1 Bottom Mount Pressure Indicator, 1/4" MNPT, 0-15 psig range, 2 1/2" face, MAWP 490 psig

NEIF 04 1 Needle Valve 1/4" FNPT x 1/4" FNPT, MAWP 6000 Psig (PG Isolation)

BAFF 03 1 NEO Cat. Ball Valve 1/4" NPT, CSA 3.16 Certified, MAWP 2000 psig (Pilot Block)

INSTRUMENT FUEL GAS:

BAFF 44 1 Ball Valve 1" NPT,Reg Port, MAWP 2000 psig (Fuel gas inlet isolation)

PRV 110 1 67 CFR Pressure Regulator, 1/4" NPT, 0-35 psig range, MAWP 250 psig (vented)

BAFF 20 1 Ball Valve 1/2" NPT, Reg port, MAWP 2000 psig (Regulator isolation)

INSULATION:

Heater shell & expansion tank shell c/w top end plate .to be insulated with 1 1/2" thick fiberglass insulation c/w embossed 0.020" aluminum cladding

STRUCTURAL SKID:

Line Heater to be mounted on 7'-0" Wide x 20'-6" long sub skid

Main Member W10 @ 19#

4 Lift Lugs

INSTRUMENT ENCLOSURE:

SIZE & TYPE: 2'-6" x 5'-0" x 3'-0" Shed Type Roof

EXTERIOR: 22 Ga. Galvalume Foam Insulated Panels, Non-painted

INTERIOR: R12 Walls

DOORS: (1) Set of Double Doors c/w Whitcomb Lock, Checkchain and Weather-stripping

VENTILATION: (1) 8" x 8" Vent c/w Slide Closure???????????????????????

OTHERS: Cut-Outs and Flashings?????????????????

ELECTRICAL:

No electrical included.

PIPING:

All piping will be constructed in accordance with ASME B31.3 latest edition for normal service and with reference to Rushton Pipe Specifications "C" & "A".

All Piping C.A. to be 1/16" for sweet service

All Piping 2" and Larger to be SA-106B Welded Construction

All Piping Under 2" to be SA-106B Threaded Construction

All Flanges to be SA-105N

All Weld Fittings to be SA-234-WPB

All Threaded Fittings to be CL 3000, SA-105N

All Bolting to be SA-193-B7M / SA-194-2HM

All Gaskets to be, 1/8" Thk, 304SS Spiral Wound, Flexitallic, Non-Asbestos Filler

All Instrument Air/Gas tubing to be 1/4" Dia. (0.035" W.T.) 316 SS c/w Swagelok or Parker CAD plated Tube Fittings

All Drain Tubing to be 1/2" Dia. (0.035" W.T.) 316 SS c/w Swagelok or Parker A-Lok CAD plated Tube Fittings

All normally venting gas instruments to be vented locally outside the enclosure wall.

All normally venting air instruments to be vented locally inside the enclosure wall.

INSPECTION / TESTING:

Piping
All piping shall have 100% of the welds fully radiographed and interpreted in accordance with the normal fluid service requirements of paragraph 341 of the current edition of the ASME B31.3 Code.

Rushton takes exception to PWHT for piping as we have welding procedures that conform to NACE standard hardness. Materials will use select chemistry & no materials used will exceed 200 HBN.

Welded piping to be hydro tested to 1.5 times design pressure.

Heater:

Line Heater and firetube to be leak tested using standing water method & visually inspected for leaks.

Ansi In: 900

Ansi Out: 900

Mawp In: 1335

Mawp Out: 1335

Certified Report

Location
Yard

Rushton Gas & Oil Equipment Sherwood Park

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

N/A

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

Yes

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Sherwood Park, Alberta

Documents

3.0 MMBTU Sour 900# Line Heater 6 Inlets 1
3.0 MMBTU Sour 900# Line Heater 6 Inlets 1
3.0 MMBTU Sour 900# Line Heater 6 Inlets 1

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Related Listings