36" x 10' 1440 PSI Sour Horizontal Separator Package

Contact for Pricing

Sold

Listing Details

CategorySeparator
Listing ID14232
StatusSold
CertificationFuelled Certified
Year2005
Make/ManufacturerNusco Company
ServiceSour
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Vessel Details
Diameter36"
OrientationHorizontal
Pressure Rating1,440 PSI
Vessel detailsDimensions: 36
Notes

Description: Separator Tag*
W RT-1 HT
MAWP: 1440 PSI at 100°F
MDMT: -20°F at 1440 PSI
Serial: 010259-200
Year: 2005
Design Press: 1440 PSI at 100°F
Corr Allow: 0.125" (3.18mm)
Head MAT'L: SA-516-70N
Head THK: 1.5"
Shell MAT'L: SA-516-70N
Shell THK: 1.5"
CRN: T4816.231
A#: 525241

Scrubber Vessel Tag*
W RT-1
Serial: 010462-202
Year: 2005
MAWP: 250PSI at 250°F
MDMT: -20°F at 250 PSI
Corr Allow: 0.125"
Head MAT'L: (Top) SA-234-WPB (Bottom) SA-516-70-N
Head THK: (Top) 0.282" (Bottom) 0.750"
Shell MAT'L: SA-106-B
Shell THK: 0.322"
CRN: OH6228.231

Natural Gas Scrubber Tag*
Model: NGS-12
Max Press/Temp: 250PSI at 200°F
Serial: W010099
CRN: OH6573.213

Certified Report

Location
Yard

Ovintiv - D-59-A

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

Yes

Equipment still welded down to piles

Yes

Equipment on a gravel pad

No

Electrical still connected to the equipment

Unknown

Have vessels been cleaned out

Unknown

Shiploose items

Yes

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Dawson Creek, British Columbia

Documents

36" x 10' 1440 PSI Sour Horizontal Separator Package 1
36" x 10' 1440 PSI Sour Horizontal Separator Package 1

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support

Other Listings In This Package

D-59-A / 93-P-8
View package