50 kW ET-50 4000 ELECTRA THERM Waste Heat Generator Package

CAD $160,000 OBO

Listing Details

CategoryGenerator
Listing ID22302
StatusAvailable
# of Units Available1
PriceCAD $160,000 OBO
Deal PreferenceFor Sale
Price TypeTotal
Package02-08-24-12W4 - Waste Heat Generators
CertificationFuelled Certified
Year2012
Make/ManufacturerELECTRA THERM
ModelET-50 4000
Serial Number4166
CO2E Savings26.94 Tonnes
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Generator Details
Frequency60 Hz
Voltage480V / 208V Volts
Driver Details
Driver TypeElectric Motor
Notes

Unit: BU401

Generator Tag*
Manufacturer: ELECTRA THERM
Model: ET-50 4000
Serial: 4166
Generator: 50 kW
Phase: 3
Frequency: 60 Hz
Voltage: 480V / 208V
Ampere: 72.4A
Locked Rotor Amps: 364A
Short Circuit Current Rating: 50 kA
Feed From MCC: E-12
SKID: 53252

Control Panel Tag*
Manufacturer: ELECTRA THERM
Model: ET-50 4000 AC
Serial: 4166
Year Built: 2012
Tare Weight: 2790 KG
High Side MAWP: 240 PSI @ MAT 116 C
Low Side MAWP: 145 PSI @ MAT 50 C Min Temp 0 C
Hot Water MAWP: 145 PSI @ MAT 116 C Min Temp 0 C
Max Hot Water Flow Rate: 45 m^3/hr
Operational Hot Water Temp Range: 88-116 C
Refrigerant: R-245fa
Min Refrigerant Charge: 390 kg
Oil: RL 100
Oil Charge: 19.5 kg

Sea Can Tag*
Type: SP-XDST-20D
Manufacturers #: HT 090 382
Year Built: 2011
Identification #: CPIU 033703 6
Max Gross Weight: 67,200 lb
Allowable Stacking Weight for 1.8G: 423,280 lb
Racking Test Load Value: 33,600 lb

O2 Monitor Tag*
Manufacturer: Thermal Gas Systems Inc.
Model: Oxyguard

Heavy Duty Safety Switch Tag*
Manufacturer: Square D
Amps: 30
Vac: 600
Vdc: 600

Heat Exchanger Tag 1*
Manufacturer: SWEP
Year Built: 2012
Serial: 312127212000034
Type: B200THx90/1P-SC-M
MAWP: 1000 PSI at 135 C
Volume: 647.0985 L

Heat Exchanger Tag 2*
Manufacturer: SWEP
MAWP: 707.64 PSI at 365 F
MDMT: -319 F at 707.64 PSI
Serial: 312127492000031
Year Built: 2012
Type: B400THx124

Compressor Tag*
Manufacturer: Howden
Serial: EXP0001/00073
Hydraulic Test Pressure: 537 PSI
Max Work Press High Side: 305 PSI
Max Work Press Low Side: 73 PSI
Max Output Speed: 5000RPM

Vessel Tag*
Certified By: Stewart Tool Company
MAWP: 150 PSI at 121 C
MAWP External: 15 PSI at 121 C
MDMT: -29 C at 150 PSI
Serial: 0036
Year Built: 2012

Cooler Tag*
Manufacturer: GUNTNER
CRN: OH9284.213467890TYN
OH12157.5
Rated Working Press: 247 PSI
Year Built: 2013

Certified Report

Location
Yard

02-08-24-12W4

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

No

Equipment still welded down to piles

No

Equipment on a gravel pad

No

Electrical still connected to the equipment

No

Have vessels been cleaned out

Unknown

Shiploose items

Unknown

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsAB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Notes

A

Need Help?


Questions? Call us at 1-855-383-5533

Log in to contact Fuelled

Virtual Tour

Location

Drumheller, Alberta

Documents

50 kW ET-50 4000 ELECTRA THERM Waste Heat Generator Package 60
50 kW ET-50 4000 ELECTRA THERM Waste Heat Generator Package 62

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support
Certificate of Environmental BenefitThis Certificate is Proudly Presented toYour CompanyEquipmnent Description: 50 kW ET-50 4000 ELECTRA THERM Waste Heat Generator Package*Total CO2E Tonnes Saved: 26.94Reutilizing this equipment from Fuelled is saving a minimum of 26.94 tonnes of CO2E which isequivalent to removing 5.9 passenger vehicles off the road for 1 year.Your NameSignatureDate* Calculated using Fuelled's proprietary emmissions calculator which comeswith certain assumptions and as compared to new manufacturing.

Other Listings In This Package

02-08-24-12W4 - Waste Heat Generators
View package