Listing Details
Category | CompressorPackage |
---|---|
Listing ID | 14362 |
Status | Sold |
Certification | Fuelled Certified |
Year | 2010 |
Make/Manufacturer | Enerflex |
Service | Sour |
Condition | Used |
Fuelled Condition Rating | Condition A New/Unused Equipment Condition B Ready to go into operation with minor service (tune-up). Used but has been overhauled. Condition C Requires Overhaul but components are present and not damaged/used beyond repair. Condition D Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair. Condition E Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver). |
Compressor Package Details | |
Stages | 3 |
Compressor Details | |
Compressor Type | Reciprocating |
Compressor Details | Cylinder Size: 2 x (10.375) x 2 x (6.750) |
Driver Details | |
Driver Type | Engine |
Driver Fuel Type | Unknown |
Driver Horse Power | 2,370 HP |
Notes | |
Description: Compressor Building (EST): 29.5' W x 42' L x 24' T | 3 sections (center 14" wide – 150,000 LBS, two outside sections 7.75' wide – 15,000 LBS each). Walls and roof will need to be removed.
Air-X-Changers:
1st Stage Suction Bottle:
2nd Stage Suction Bottle:
Control Panel:
Driver:
Frame:
Field Gote/Trail
Sub Type: REMVUE 500 Brand 2: Ariel Model 2: JGC/4 Make 3: CATERPILLAR Model 3: G3608TA-LE Serial Number 3: BEN00648 Make 4: Air-X-Changer Model 4: 108 F3S Make 5: Spartech Manufacturing Rated Rpm 3: 1000 Building Enclosure: yes | |
Certified Report
Location | |
Work Site | EOG - Gote - C-18-B |
---|---|
Status | |
Equipment Still in Operation | No |
Does the skid have skirting that needs to be removed | Yes |
Equipment still connected to piping | Yes |
Equipment still welded down to piles | Yes |
Equipment on a gravel pad | No |
Electrical still connected to the equipment | Yes |
Have vessels been cleaned out | Unknown |
Shiploose items | Unknown |
Service | |
Has equipment been preserved? If so, when? | Unknown |
Site Logistics | |
Equipment accessibility in yard or work site | |
Access into work site | |
Any road use agreement to access site | Yes |
Vessel Registrations | |
Provincial Vessel Registrations | AB, BC, SK |
Equipment Appearance | |
Missing Parts | |
Corrosion | |
Animal Infestation | |
Overall cleanliness of package |
Need Help?
Virtual Tour
Location
Fort Nelson, British Columbia
This equipment is Fuelled Certified.
- Visually inspected and catalogued by Fuelled trained representatives
- Immersive and credible data
- Fuelled logistical support