Dual 200HP Quintuplex Pump Package with Boosters and Filters

Contact for Pricing

Sold

Listing Details

CategoryPump
Listing ID14360
StatusSold
CertificationFuelled Certified
Make/ManufacturerTarpon Energy Services
CO2E Savings99.43 Tonnes
ServiceUnknown
ConditionUsed
Fuelled Condition Rating
B
Condition A
New/Unused Equipment

Condition B
Ready to go into operation with minor service (tune-up).
Used but has been overhauled.

Condition C
Requires Overhaul but components are present and not damaged/used beyond repair.

Condition D
Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair.

Condition E
Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver).
Pump Details
Pump details3"x2" 1800RPM
Driver Details
Driver TypeElectric Motor
Driver Fuel TypeUnknown
Driver Horse Power200 HP
Driver details200HP 3PH 460V 1785RPM Driver Type: Electric Driver
Notes

Description: Tarpon Energy Services Tag*
FAB: Auscan Design LTD
Volts: 24VDC/120VAC/240VAC/480VAC
Amps: 30A/60A/412A
Phase: 1 and 3
Cycles: 60Hz
Class: 1
Zone: 2
ProJ#: AUSCAN/E06
Job #: 1002-0074

Brook Crompton Tag*
Model: 1DN
FR: 4471Z
Serial: 2LB028
PH: 3
Class : F
Rating: CONT
D.E: NU319 C3
N.D.E: 6319C3
AMB Temp: 40°C
Useable On: 208V
HP: 200
Volts: 460
SF: 1.25
AMPs: 219
RPM: 1785
NOM PF: 0.90
DES: B
AMPS: 875
Code: H
NOM EFF: 0.95

Status Flow Stabilizer Tag 1*
Stabilizer Model: SFTSC1506F30
Serial: 8220
Max Press: 150 PSI
Ref #: 0H09038.2
Cartridge Model: SFT242N
Cartridge Serial: SF2N409108
Max Charge PSI: 100

Status FLow Stabilizer Tag 2*
Stabilizer Model: SFTD021003F30011
Stabilizer Serial: 8231
Max Press: 2100 PSI
Reference #: 0H09038.2
Cartridge Model: SFT246N
Cartridge Serial: SF6N02104S
Max Charge PSI: 500

Eagle Pump Tag*
Model: A-100N
Size: 3x2-108S
Capacity: 180USF
TDH/PSI: 93.3 / FEET
RPM: 1800
Serial: A10-1591-004
PO No: 3490-294

Sour Produced Water Tank (x2) Tag*
Serial: VE4707A1
Model: LTA20-412-2F-150E84
CRN: K7608.1
MAWP: 150 PSI at 250°F
MDMT: -20 PSI at 150 PSI
Hydro Test: 195 PSI

Eagle Pump Tag*
Model: A-100M
Size: 3x2-10SS
Capacity: 180USGPM
TDH/PSI: 97.3 /FEET
RPM: 1800
Serial: A10-16591-005
PO NO: 3490-294

Brook Crompton Tag*
Model: 1DN
FR: 447TZ
Serial: 3880012
PH: 3
Class : F
Rating: CONT
D.E: NU319 C3
N.D.E: 6319C3
AMB Temp: 40°C
Useable On: 208V
HP: 200
Volts: 460
SF: 1.25
AMps: 219
RPM: 1785
NOM PF: 0.90
DES: SF
AMPS: 875
Code: H
NOM EFF: 0.95

Power Zone Equipment Tag*
Work Order: 10294-A

Status Flow Stabilizer Tag*
Stabilizer Model: SFTSC1506F300N
Stabilizer Serial: 8225
Max Oper Press: 150 PSI
Ref No: OH09038.2
Cartridge Model: SFT246N
Cartridge Serial: SF6N021018
Max Charge PSI: 500

Rotork Tag*
Serial: CD33960102
Wiring Diagram: 3001-000-06
Actuator Type: IQS 12 FA10B4
Model: IQFM
Speed: 57 RPM
Torque Max: 40.00Nm
NEMA/Enclosure: 6/WT
Temp Code: T4
Lubrication: SAE80EP
Motor Rating: 0.34kw 15min
Motor Supply 120 1 60
Nom Motor: 2.50 AMP
Year: 2017

Building Enclosure: yes

Certified Report

Location
Work Site

EOG - Tattoo - D-35-E

Status
Equipment Still in Operation

No

Does the skid have skirting that needs to be removed

No

Equipment still connected to piping

Yes

Equipment still welded down to piles

Yes

Equipment on a gravel pad

No

Electrical still connected to the equipment

Unknown

Have vessels been cleaned out

Unknown

Shiploose items

Yes

Service
Has equipment been preserved? If so, when?

Unknown

Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site

Yes

Vessel Registrations
Provincial Vessel RegistrationsBC
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package

Need Help?


Virtual Tour

Location

Fort Nelson, British Columbia

This equipment is Fuelled Certified.

Benefits to purchasing Fuelled Certified equipment:
  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support
Certificate of Environmental BenefitThis Certificate is Proudly Presented toYour CompanyEquipmnent Description: Dual 200HP Quintuplex Pump Package with Boosters and Filters*Total CO2E Tonnes Saved: 99.43Reutilizing this equipment from Fuelled is saving a minimum of 99.43 tonnes of CO2E which isequivalent to removing 21.6 passenger vehicles off the road for 1 year.Your NameSignatureDate* Calculated using Fuelled's proprietary emmissions calculator which comeswith certain assumptions and as compared to new manufacturing.