Category | RefrigerationPlant |
---|---|
Listing ID | 22583 |
Status | Available |
# of Units Available | 1 |
Deal Preference | For Sale |
Price Type | Total |
Package | 10 MMSCFD Hay Butte Gas Plant |
Certification | Fuelled Certified |
Year | 2013 |
Make/Manufacturer | TEX-FAB |
Serial Number | 17338 |
Service | Sweet |
Condition | Used |
Fuelled Condition Rating | Condition A New/Unused Equipment Condition B Ready to go into operation with minor service (tune-up). Used but has been overhauled. Condition C Requires Overhaul but components are present and not damaged/used beyond repair. Condition D Requires Overhaul and major components (vessels, engine, instrumentation, piping, panel, etc.) are missing or damaged beyond repair. Condition E Scrap or suitable for parts. Major item(s) missing (I.e. Separator Package missing separator vessel or Compressor Package missing driver). |
Refrigeration Plant Details | |
Cooler Make | CHART |
Cooler Model | 1-HF16S-3-50 |
Cooler Serial Number | 49712 |
Plant Type | Mechanical Refrigeration |
Compressor Details | |
Compressor Make | MYCOM |
Compressor Model | P250VLD |
Compressor Serial Number | 2517012R |
Compressor Type | Screw |
Compressor Cylinder Count | 1 |
Vessel Details | |
Design Pressure Rating | 1,200 PSI |
Driver Details | |
Driver Type | Electric Motor |
Driver Fuel Type | Unknown |
Notes | |
Unit Tag: T-2010
Deethanizer Tower Tag*
Gas Chiller Tag*
**18" x 30' 180 PSI Stabilizer Package**
*Dual Siemens MYCOM P250VLD Sweet Screw Compressor Package*
General Comp. Package Tag 1*
Screw Compressor Tag2*
General Comp. Package Tag2*
**CHART HF16S Propane Condenser Cooler**
**CHART SF120 Single Service Glycol Cooler**
| |
Certified Report
Location | |
Yard | Williston Yard 1 - Alexander, ND |
---|---|
Status | |
Equipment Still in Operation | No |
Does the skid have skirting that needs to be removed | No |
Equipment still connected to piping | Yes |
Equipment still welded down to piles | No |
Equipment on a gravel pad | Yes |
Electrical still connected to the equipment | Yes |
Have vessels been cleaned out | Unknown |
Shiploose items | Yes |
Service | |
Has equipment been preserved? If so, when? | Unknown |
Site Logistics | |
Equipment accessibility in yard or work site | |
Access into work site | |
Any road use agreement to access site | Unknown |
Equipment Appearance | |
Missing Parts | |
Corrosion | |
Animal Infestation | |
Overall cleanliness of package | |
Notes | |
A53999 A54000 A54005 A54008 A53991 A53992 A53994 A53995 |