Listing Details

20 MMSCFD Refrigeration Plant w/ Glycol System and De-Ethanizer (Plant 3)

Take a Virtual Walk Through

Listing ID 13906
Status Available
# of Units Available 1
Deal Type Outright Sale
Service Sweet
Year Built 2007
Manufacturer ALCO Gas & Oil
Fuelled Condition Rating B
This is a rating derived by Fuelled via a visual inspection.
Condition Used
Last Inspection 2017
Warranty No
Notes Gas Chiller Tag*
Serial: 2007-7796-02
CRN: U-3754.2
Year: 2007
MAWP: 700 PSI at 150°F
MAEWP: 0 PSI at 150°F
MDMT: -20°F at 700 PSI
Tag: TUBESIDE
CA: 0.0625
Hydro: 910 PSI

Flame Arrested Burner Tag*
Serial: 0710-696
Model: FAB18-12A
Burner: 2-1/2
Orf Size: MTD16
BTU: 600000
Arrestor Size: 20"
Energy Input: 356425 BTU
Max Input: 965,982 BTU
Main Burner Press: 11 PSI

Compressor Tag*
Serial: 882773
Model: P8WB
LEAK (PSIG): HP 313 / LP185
HYD (PSIG): HP 470 / LP 470

Packed DE-Ethanizer Tower Tag*
Serial: 2007-7796-05
CRN: U-3630.2
A#: 584433
Year: 2007
MAWP: 400 PSI at 150°F
MAEWP: 0 PSI at -20°F at 400 PSI
CA: 0.0625
HYDRO: 520 PSI
Head: SA516-70MT / 0.28"
Shell: SA106B / 0.375"

Propane Suction Scrubber Tag*
Serial: 2007-7796-08
CRN: U-3652.2
A#: 584457
Year: 2007
MAWP: 300 PSI at 200°F
MAEWP: 0 PSI at 200°F
MDMT: -20°F at 300 PSI
CA: 0.0625"
Hydro: 390 PSI

Heating Coil Tag*
Serial: 2007-7796-08
CRN: U-3652.2
Year: 2007
MAWP: 1350 PSI at 200°F
MAEWP: 300 PSI at 200°F
MDMT: -20°F at 1350 PSI
CA: 0.0625"
Hydro: 1755 PSI

3PH Glycol Flash Tank Tag*
Serial: 2007-7786-07
CRN: U-3622.2
A#: 584437
MAWP: 150 PSI at 200°F
MAEWP: 0 PSI at 200°F
MDMT: -20°F at 150 PSI
CA: 0.0625"
Hydro: 195 PSI

Low Temp Separator Tag*
Serial: 2007-7796-03
CRN: U-3756.2
A#: 584438
Year: 2007
MAWP: 700 PSI at 150°F
MDMT: -20°F at 700 PSI
CA: 0.0625"
Hydro: 910 PSI

Technical Data

Location Map

Product Location Map

Edson, Alberta , Alberta

Certified Report

Fuelled Certified Report

Print
Location
Location Yard
Peyto - 09-34-053-20 W5M
Status
Equipment Still in Operation No
When was equipment last run
Does the skid have skirting that needs to be removed No
Equipment still connected to piping Yes
Equipment still welded down to piles Yes
Equipment on a gravel pad No
Electrical still connected to the equipment Yes
Have vessels been cleaned out Unknown
Shiploose items No
Service
Hours since last major service? If so, how many?
Has equipment been preserved? If so, when? Unknown
Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site Yes
Vessel Registrations
Provincial Vessel Registrations AB
CRN: U-3754.2
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Operator Notes/Interview/Other Comments

Log in to contact seller

This equipment is Fuelled Certified.

Fuelled Certified March 2021

Benefits to purchasing Fuelled Certified equipment:

  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support
  • Fuelled technical support
  • Financing options