Listing Details

36" x 26' 2152 PSI 0.75 MMBTU Sour Dehydrator Package

Take a Virtual Walk Through

Listing ID 14309
Status Available
# of Units Available 1
Deal Type Outright Sale
Service Sour
Year Built 2008
Manufacturer Opsco
Fuelled Condition Rating B
This is a rating derived by Fuelled via a visual inspection.
Condition Used
Warranty No
Diameter 30
MAWP 2125
Reboiler Duty (btu/hr) .750MMBTU
Num Trays 8
Notes Dehydrator Tag*
Mawp: 2152 Psi @ 130º F
Mdmt: -20º F @ 2152 Psi
Serial #: 01-0141-1
Year Built: 2008
CRN: U5433.213
Tag #: V-600
Coil Mawp: 2152 Psi @ 130º F
Coil Mdmt: -20º F @ 2152 Psi
A #: 586792



Reboiler Tag:
Serial #: REB-010141-01-001 Rev.1
Fuel: Sour Nat Gas
Fuel Supply Pressure: 1000 Psig
Manifold Pressure: 5-18 Psig
Maximum HR Input: 1,071,429 btu/hr
Output Rating: 0.750MMBTU
Electrical: 24V DC / 2.45 Watts


Filter Vessel tag*
Serial @: JL2008-059
CRN: R1288.2134
Mawp: 350 Psi @ 200º F
Mdmt: -20º F @ 350 Psi
Year Built: 2008



Flame arrested Burner Tag*
Model: FAH20-10A
Btu: 0.750MMBTU
Burner: 2 1/2
ORF Size: 3/16
Serial #: 0805-682


Glycol Reconcentrator: Duty: 1,250,000 BTU/HR, 48" OD x 16'
LG Reboiler: 42" OD x 13'-6"
LG Surge Tank: 18" OD Firetube, 18" OD x 18'
High Stack: 18" OD x 12'6"
LG SS Still Column: 1,000,000 BTU/HR Flame Arrestor
Glycol Contactor: 8 Tray, 36" OD x 26' S/S 3-Phase, DP 2152PSIG incl.
Hydrostatic Pressure: @ 130F, MAWP 2162PSIG @ 130F, MDMT -20F, CA 0.125"
Gas/Glycol Exchanger: 10" NPS Outer Pipe (SCH160), 6" NPS Inner Pipe (SCH160),
DP 2220PSIG @ 130F CA 0.125", Max Diff. Pressure 700PSIG @ 130F
Glycol Regen: 36" OD x 14' REB./ 11' Acc. Long, 750,000 BTU/HR 12.75" OD Firetube & Stack,
Accumulator: 1" SA-179 Tubing Coil, Fuel Gas Pre-HT: Two Passes, 1" SCH XXH, SA-106B,
Still Column: 12.75" OD x 2' Long.
Scubber: 6.625" OD x 28" Long, DP 270 PSIG @ 150F, Model Opsco DP SMF 628, CA 0.0625"
Air/Glycol Exchanger: Two Banks, 1" x 10'
Catadyne Building Heater: 16,000 BTU/HR, 120VAC Start C/W Vent Hood
Glycol Pump, Bruin, Model 450-15, 9014
Exhaust Fans, Part # JE125901PXP, 120V AC / 1 PH

Technical Data

Technical Data

No attachments supplied.

Location Map

Product Location Map

Fort Nelson , British Columbia

Get Directions

Certified Report

Fuelled Certified Report

Print
Location
Location Work Site
EOG - Maxhamish - D-36-L
Status
Equipment Still in Operation N/A
When was equipment last run
Does the skid have skirting that needs to be removed No
Equipment still connected to piping Yes
Equipment still welded down to piles Yes
Equipment on a gravel pad No
Electrical still connected to the equipment Unknown
Have vessels been cleaned out Unknown
Shiploose items No
Service
Hours since last major service? If so, how many?
Has equipment been preserved? If so, when? Unknown
Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site N/A
Vessel Registrations
Provincial Vessel Registrations AB, BC, SK
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Operator Notes/Interview/Other Comments

Log in to contact seller

This equipment is Fuelled Certified.

Fuelled Certified June 2021

Benefits to purchasing Fuelled Certified equipment:

  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support
  • Fuelled technical support