Listing Details

3.5 MMBTU/HR Direct Fired Amine Reboiler

Listing ID 11376
Status Available
# of Units Available 1
Deal Type Outright Sale
Notes Originally part of a 30 MMSCFD Amine Plant
The direct fired reboiler has been removed from the site and is yard stored.

AMINE REBOILER (SUBJOB -60)
- 3.5 MMBTU/hr (8,000 BTU's/hr/ft flux rate)
- 66" O.D. x 40'0" S/S X 50 psig @ 300ºF/-20ºF MDMT
- 0.125” C.A
- SHELL: 66" O.D. x 3/8" thick SA-516-70N plate
- HEADS: 66" O.D. x 3/8” thick 2:1 S.E. SA-516-70N plate
- FIRETUBE: 24" O.D. x 0.500” wall x 34’-0” SA-516-70N
- 100% radiography (per RT-1), PWHT
- STACK: 0.188” wall x 20’-0” ERW self supporting
- five (5) piece mitre
- burner assembly and fuel gas train supplied / installed by others
- INSULATION: 1 1/2" AF-530 fibreglass insulation c/w flat aluminum
jacket
- FUEL GAS PREHEAT COIL:
- 1" sch 80 SA-106B
- Design Int. Pressure: 285 psig @ 300ºF/-20ºF (0.0625” c.a)
- Design Ext. Pressure: 75 psig @ 300ºF/-20ºF ( 0.125” c.a)
- lift lugs
- integral 3’-6” surge capacity d/s of wier
- instrument enclosure (B-800)
- CRN #: T3485.2

Connections:
2 - 4" 150# RFWN nozzles (vapour outlets)
2 - 4" 150# RFWN nozzles (amine inlets)
1 - 4” 150# RFWN nozzle (amine outlet)
2 - 2" 150# RFWN nozzles (truck outs)
1 - 2" 150# RFWN nozzles (truck in)
4 - 2" 150# RFWN nozzles (TI, TT, TSHH, purge gas)
9 - 2" 150# RFWN nozzles (LG, LSL, LSLL, PI)
2 – 1” 6000# NPT coupling (fuel gas preheat)
1 - fabricated firetube manway, SA-516-70N
1 - 20" 150# RF manway c/w blind flange, bolting and davit
1 - 3” 150# RFWN nozzle (PSV)

Technical Data

Location Map

Product Location Map

Athabasca, Alberta, Alberta

Certified Report

Fuelled Certified Report

Print
Location
Location Yard
Athabasca, Alberta
Status
Equipment Still in Operation No
When was equipment last run
Does the skid have skirting that needs to be removed No
Equipment still connected to piping No
Equipment still welded down to piles No
Equipment on a gravel pad No
Electrical still connected to the equipment No
Have vessels been cleaned out Yes
Shiploose items Yes
Service
Hours since last major service? If so, how many?
Has equipment been preserved? If so, when? Unknown
Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site No
Vessel Registrations
Provincial Vessel Registrations
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Operator Notes/Interview/Other Comments

Log in to contact seller

This equipment is Fuelled Certified.

Fuelled Certified November -0001

Benefits to purchasing Fuelled Certified equipment:

  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support
  • Fuelled technical support
  • Financing options

Related Products

Added to Wishlist

Alberta, Canada

Compare

Inquire

Added to Wishlist

Alberta, Canada

Compare

CAD $15,000 OBO

Added to Wishlist