Listing Details

60" x 32' 2050 PSI Sour Gas Dehydration Package

Take a Virtual Walk Through

Listing ID 13909
Status Available
# of Units Available 1
Deal Type Outright Sale
Service Sour
Year Built 2012
Manufacturer ALCO Gas & Oil
Fuelled Condition Rating B
This is a rating derived by Fuelled via a visual inspection.
Condition Used
Warranty No
Diameter 60
MAWP 2050
Capacity 70
Flash Tank Yes
Pump Style Electric
Reboiler Duty (btu/hr) 1000000
Num Trays 10
Notes 1 MMBTU Reboiler

2PH Glycol Contractor Tower Tag*
Serial: 2011-8267-01
CRN: ALD-12-004
A#: 620317
Year: 2012
MAWP: 2050 PSI at 150°F
MAEWP: 0 PSI at 150°F
MDMT: -50°F at 2050
Service: RT-1 HT
Head MAT'L: SA516-70MT
Head THK: 3.350"
Shell MAT'L: SA516-70MT
Shell THK: 3.500"
Tag: V-300
CA: 0.125"
Hydro: 2665 PSI

Tower Heating Coil Tag*
Serial: 2011-8267-01
CRN: ALD-12-004
MAWP: 2050 PSI 150°F
MAEWP: 2050 PSI at 150°F
MDMT: -50°F at 2050PSI
Year: 2012
Head MAT'L: SA350LE2 CL1 RFWN
Head THK: 0.344"
Shell MAT'L: SA333-6/420WPL6
Shell THK: 0.436"
CA: 0.125"
Hydro: 2665 PSI

Glycol Pump (x2) Tag*
Driver:
Serial: AC-172058
Model: EL122
Catalog: ELP15P2D
Type: ELP
Frame: 254T
PH: 3
INS. CL: F
Duty: Continuous
AMB: 40°C
ID: R12C
DE/ODE BRG: 6309
HZ: 60
HP: 15
RPM: 1775
V: 208-230/460
A: 36.6-34.6/17.3
Max KVAR: 6.5 / 6.2
SF: 1.3 / 1.05
SFA: 21.7 / 21.7
Nom PF: 88.0 / 89.0
Nom EFF: 92.4 / 91.2
Gar EFF: 91.4 / 90.0
Design Press: A / A
Code: K / H

CoorsTek Cartridge:
Serial: 01216057A
Year: 2012
Model: 100-U-21002-F
CRN: OH5670.213
MAWP: 2100 PSI at 150°F
MDMT: -20°F at 2100 PSI

Glycol Flash Tank Tag*
Serial: 2011-8267-09
CRN: V-7651.2
A#: 618277
Year: 2012
MAWP: 250 PSI at 200°F
MAEWP: 0 PSI at 200°F
MDMT: -20°F at 250 PSI
Tag: V-302
CA: 0.125“
Hydro: 325 PSI

Technical Data

Technical Data

Location Map

Product Location Map

Rocky Mountain House , Alberta

Certified Report

Fuelled Certified Report

Print
Location
Location
Status
Equipment Still in Operation
When was equipment last run
Does the skid have skirting that needs to be removed
Equipment still connected to piping
Equipment still welded down to piles
Equipment on a gravel pad
Electrical still connected to the equipment
Have vessels been cleaned out
Shiploose items
Service
Hours since last major service? If so, how many?
Has equipment been preserved? If so, when?
Site Logistics
Equipment accessibility in yard or work site
Access into work site
Any road use agreement to access site
Vessel Registrations
Provincial Vessel Registrations
Equipment Appearance
Missing Parts
Corrosion
Animal Infestation
Overall cleanliness of package
Operator Notes/Interview/Other Comments

Log in to contact seller

This equipment is Fuelled Certified.

Fuelled Certified April 2021

Benefits to purchasing Fuelled Certified equipment:

  • Visually inspected and catalogued by Fuelled trained representatives
  • Immersive and credible data
  • Fuelled logistical support
  • Fuelled technical support
  • Financing options

TAQA - 01-04-044-11 W5M